Water purification information

Introduction of various indexes of reverse osmosis membrane

Views : 70668
Update time : 2021-09-27 17:47:07
1. Desalination rate and salt permeability of reverse osmosis membrane
reverse osmosis membrane

Salt permeability = product water concentration / influent water concentration × 100%

Desalination rate = (1-salt content of product water / salt content of influent water) × 100%

Salt penetration rate = 100%-desalination rate

The desalination rate of the membrane element is determined when it is manufactured and formed. The desalination rate depends on the density of the ultra-thin desalination layer on the surface of the membrane element. The denser the desalination layer, the higher the desalination rate and the lower the water production.

The desalination rate of different substances by reverse osmosis is mainly determined by the structure and molecular weight of the substance. The desalination rate of high-valent ions and complex monovalent ions can exceed 99%, and the desalination rate of monovalent ions such as sodium ions, potassium ions, and chloride ions is slightly lower. , But it also exceeds 98%; the removal rate of organics with a molecular weight greater than 100 can also exceed 98%, but the removal rate of organics with a molecular weight of less than 100 is low.

2. Water production of reverse osmosis membrane
reverse osmosis membrane
Water production-refers to the water production capacity of the reverse osmosis system, that is, the amount of water permeating the membrane per unit time, usually expressed in tons/hour or gallons/day.

Permeation flow rate-is also an important indicator of the water production of reverse osmosis membrane elements. Refers to the flow rate of permeate per unit membrane area, usually expressed in gallons per square foot per day (GFD). Too high permeate flow rate will cause the water velocity perpendicular to the membrane surface to increase, which will aggravate membrane fouling.

3. Recovery rate of reverse osmosis membrane

Recovery rate-refers to the percentage of feed water converted into product water or permeate in the membrane system. Depends on the pretreatment influent water quality and water requirements. The recovery rate of the membrane system has been determined at the time of design,

Recovery rate = (product water flow/influent flow) × 100%

For large RO systems, the recovery rate is usually limited by the tendency of insoluble salt to foul, that is, by the maximum concentration of concentrated water; for small RO systems, the recovery rate is usually less than 30% to 50%. When the recovery rate is low, the RO device can operate safely without controlling the solubility of insoluble salts. Cost is usually not a priority for small RO systems.
Related News
Read More >>
Application of water purifier in public places: guarding every drop of healthy water source Application of water purifier in public places: guarding every drop of healthy water source
Sep .14.2024
In today's society, with people's pursuit of a healthy life and increasing concern for environmental quality, water purifiers, as an effective water treatment equipment, is gradually playing an increasingly important role in public places. Schools, hospitals, offices and other public places, due to the high flow of people, high demand for water, water quality requirements are more stringent. Therefore, the application of water purifiers in these places is particularly important.
Reverse osmosis ultrapure water system how to maintain can improve life expectancy Reverse osmosis ultrapure water system how to maintain can improve life expectancy
Sep .14.2024
In recent years, people's requirements for water quality is more and more high, in order to meet people's needs, reverse osmosis ultrapure water system is therefore born, and meet the public recognition. In order to protect the performance and stability of reverse osmosis membrane treatment, and the need to do a good job of maintenance, equipment maintenance in order to water quality in order to be more stable, so we have organized the following several maintenance methods, please come to understand.
Why should you install a water purifier? This article will make you understand the importance of the existence of water filters! Why should you install a water purifier? This article will make you understand the importance of the existence of water filters!
Sep .13.2024
The emergence of water purifiers, so that the way of drinking water redefined, the emergence of water purifiers is because the water quality continues to change and the emergence of a way of drinking water; from the ability to drink the river water well water to the tap water to the bucket of water, to the current exceptionally hot water purifier market, is the environment affects the way of drinking water change rather than artificial to speak of this market hype up; like cell phones, because people really need, so the market is Will be hot, if put into a few years ago, the cell phone market is also the need for everyone to introduce.
Will water purifiers replace the bottled water? Will water purifiers replace the bottled water?
Sep .13.2024
We all know that in developed countries, water treatment technology is very advanced, the street just twist open a faucet can be directly drinking water, very convenient. Comparison of China, in recent years, with the industrial development, groundwater pollution is more serious, the residents of the daily drinking water can only be bottled water or water purifier-based. In these two competing ways of drinking water, household water purifiers will further replace the bottled water market?

In this regard, Susan will analyze for you. In the current drinking water environment, is still dominated by bottled water, although the water purifier will to a certain extent impact the bottled water market, but want to completely beyond is very difficult to realize, this is because bottled water has a variety of water purifier does not have the advantage.